Soft-sensing System of Gas-Solid Fluidized Bed

HF Ji,ZY Huang,BL Wang,HQ Li
DOI: https://doi.org/10.1109/icsens.2003.1279141
2003-01-01
Abstract:Based on wavelet analysis, fractal theory and ECT (Electrical Capacitance Tomography) technique, a soft-sensing system of gas-solid fluidized bed is established, which can implement the on-line identification and the monitoring of the flow regime, and also can measure the voidage of the gas-solid fluidized bed. In this system, wavelet analysis and fractal theory are used to analyze and identify the flow regime by processing the signals of pressure fluctuation; a 12-electrode ECT system is used to display the flow state and calculate the voidage of gas-solid fluidized bed by using a novel image reconstruction algorithm. Experimental results show that the soft-sensing system is effective. It can improve the accuracy of identification of flow regime and can measure voidage of gas-solid fluidized bed with an error less than 5%.
What problem does this paper attempt to address?