Abstract:To establish a diagnosis method of hydrophobicity of composite insulator based on leakage cur-rent characteristic, the effects of pollution degree and hydrophobicity on the maximum value of leakage current, occurrence number of leakage current and accumulated discharge capacity were studied under the condition of saturated humidity, and the hydrophobicity of the composite insulator was diagnosed by clus-ter analysis method. The results show that the maximum value of leakage current increases with the in-crease of pollution degree and hydrophobicity. The pollution degree and hydrophobicity affect the the different amplitude range of leakage current. The pollution degree primarily affects the low amplitude part of leakage current, while the hydrophobicity affects the high amplitude part of leakage current, which is because the effcts of pollution degree and hydrophobicity on the surface resistance of the composite insulator are different. The effect of pollution degree on the accumulated discharge capacity of the composite insulator is more obvious. The selected leakage current characteristic can realize the diagnosis of hydrophobicity of the composite insulator by the cluster analysis method.