Study of Non-Drip Water and Humidity Measurement-Control Technology

LI Yong,ZENG Zhi-xin,LI Wei-guang,XU Jing
DOI: https://doi.org/10.3969/j.issn.1000-9787.2005.02.009
2005-01-01
Abstract:It is still difficult to resolve the condensation water drips from domestic air-conditioners and the air dry and dirty after a long air conditioning period.Principle of non-drip and humidity measurement-control technology is discussed,and humidity frequency measuring circuit,the peripheral circuit of the single chip processor and key models of software are interpreted.The results show that condensation water can be got together,the room with the conditioner can be fogged and wetted,the heat exchange efficiency of the condenser can be improved,and condensation water dripping randomly can be controlled and the air quality can be improved too.