Effect of Header Configuration on Thermal Performance of Plate-Fin Heat Exchangers

WANG Jiang,LI Yanzhong,ZHANG Zhe,MA Yansong
DOI: https://doi.org/10.3321/j.issn:0438-1157.2005.08.007
2005-01-01
Abstract:Based on the study of the flow maldistribution in plat e -fin heat exchanger,the effect of header configuration on thermal performance a nd reduction of heat exchanger efficiency caused by the flow maldistribution in heat exchanger was experimentally studied.The experimental results showed that t he effect of header configuration on the flow and temperature distribution in he at exchanger was significant.An improved header configuration not only could dec rease the time from starting to steady working condition of heat exchanger,but also make the flow and temperature distribution more uniform in heat exchanger.A t the same time,the correlation between heat exchanger efficiency and flow mald istribution characteristics was deduced from the experimental data.
What problem does this paper attempt to address?