Abstract:A gas chromatographic method for detecting residue of ethanol, ethyl formate and triethyl orthoformate in industrial water was established. The method was as follows:the three organic solvents were separated on a DB-WAX (30.0m ×250μm ×0.25μm ) using programmable increased temperature. The column temperature was initially maintained at 70℃ for 2.5min and then up to 150℃at the rate of 20℃/min for 3min, quantified by internal standard method. Each component was excellent linearity and had high percentage recovery. This method can be used for effective analysis of organic residual in industrial wastewater.