Comparative analysis of push-out tests for two kinds of GFRP shear connectors

Hailin Huang,Ao Li,Mingqiao Zhu,Yuancao Guo,Chuijun Zeng
DOI: https://doi.org/10.11835/j.issn.1674-4764.2016.05.005
2016-01-01
Abstract:Shear connectors are the important detailings affecting the mechanical properties of GFRP-concrete composite beams/decks.Rectangular rib and T-type rib GFRP shear connectors are put forward to improve the interfacial bond properties between GFRP and concrete.Eight push-out tests are conducted to evaluate the mechanical behaviors of two rectangular perforated rib GFRP shear connectors and three T-type perforated rib GFRP shear connectors,as well as three T-type rib GFRP shear connectors.The failure patterns,ultimate bearing capacities, load-slip behaviors and load-strain regularities are obtained by contrast tests.Results show that T-type perforated rib GFRP shear connectors show higher strength and better ductility than rectangular perforated rib GFRP shear connectors,and T-type perforated rib GFRP shear connectors show higher strength and better ductility than T-type rib GFRP shear connectors.An empirical equation to predict the ultimate shear resistance is proposed and validated by the experimental data.Idealized load-lip models and equations to predict the load versus slip relationship for all specimens areproposed.Curve fittings are performed to find fitting parameters for all tested specimens and the resultsshow a very good correlation with those of the experiments.An empirical equation to predict the shearrigidity is proposed.
What problem does this paper attempt to address?