Test and Analysis on Axial Performances of GFRP Restraint Connectors for Sandwich Insulation Wall Panels

Zhi-Zhou He,Peng Pan,Gen-Qi Xiao,Shao-Dong Shen,Jun-Yu Ren
DOI: https://doi.org/10.1016/j.jobe.2021.103457
IF: 7.144
2022-01-01
Journal of Building Engineering
Abstract:The sandwich insulation wall panel (SIWP) is an essential component of most building insulation systems. To achieve the satisfactory insulation effect in certain areas, such as Sweden, the thickness of insulation layer in SIWPs can reach 300 mm. However, the shear and axial compressive performances of most existing connectors at this length are unsatisfactory. The authors have previously proposed a novel GFRP connector system suitable for 60-300 mm insulation thickness, and the study on its shear behaviors has been published. This paper focuses on axial loading behaviors of the system. Three types of glass-fiber reinforced plastic (GFRP) restraint connectors, named PlateA, PlateB and Cross, were proposed. Pull-out and push-off tests were conducted to investigate their tensile and compressive failure modes. Results show that anchorage zone concrete splitting is the predominate failure mode in all pull-out tests whereas concrete punching failure is the main failure mode in push-off tests. The 300-mm-length PlateA connector and the 300&150-mm-length PlateB connectors buckled before concrete failure. The concrete failure surface was determined, and formulas to calculate axial strength of connectors based on concrete failure modes were established by theoretical and finite element analysis.
What problem does this paper attempt to address?