Numerical Analysis for Push‐Out Test with Y Type Perfobond Shear Connectors

Wajdi Mefleh,Nauzika Kovács
DOI: https://doi.org/10.1002/cepa.1822
2022-09-01
ce/papers
Abstract:This paper focuses on the Y type perfobond shear connectors of steel‐concrete composite beams with the aim to investigate the influence of the structural parameter of the connection to the resistance and ductility of the structures. The Y shaped shear connections are a new shape developed with the benefits of resisting a higher shear force by the transversal bars and a bigger area of the concrete dowels surrounded by the Y shaped plate. This type of shear connection has significant resistance against vertical separation. In this paper, an advanced finite element model for a push‐out test with a Y type perfobond shear connector has been developed and validated by the experimental test. The aim of this research is to investigate different parameters such as the concrete strength, perfobond yield stress, the existence of the transversal bars on the structural behavior. The results showed that the concrete strength has a major effect as using a higher concrete resistance gave a higher ultimate resistance with a higher ductility. The existence of the transverse bars shows a major effect on the ductility load level. On the contrary, the effect of changing the diameter of the bars on the ductility load level was slightly noticeable. While using deferent steel grades for the perfobond plate significantly affected the ultimate resistance, but not the ductility load level. In further studies more parameters will be checked, and a formula and a guideline could be developed for a design purpose.
What problem does this paper attempt to address?