Abstract:Using air as working medium, the orthogonal experiment was used to study heat and flow characteristics of turbulent flow in nine kinds of big diameter three-dimensional internally finned tube while the Reynolds number within the range of 25 000~110 000 to select the best type tube, and to obtain the experimental correlations of Nusselt number and the fanning friction factor with Reynolds number and parameters of three-dimensional internally finned tube.Results show that characteristics of three-dimensional internally finned tube is better than that tube of the same diameter, heat transfer coefficient up to three point one five times that of the light tube and thermal performance coefficient up to one point four five times, which indicates the feasibility of application in tubular heat exchanger;In addition, the biggest impact on thermal heat transfer characteristics is the rib height, spacing comes second, width is the smallest, which shows the direction of parameter optimization.