SHEAR STRENGTH OF CORRODED REINFORCED CONCRETE COLUMN WRAPPED BY FIBER SHEET WITH LARGE DUCTILITY

Chuang Zhang,Dawei Zhang,Yuxi Zhao,An Duan
DOI: https://doi.org/10.13204/j.gyjz201607032
2016-01-01
Abstract:Polyeethylene Terephthalate ( PET ) fibers were used to strengthen RC columns with corroded stirrups . Cyclic loading tests were conducted for RC column specimens to investigate the effect of PET wrapping and stirrup corrosion.It was concluded that the shear strength of the specimens decraeased with increasing of degree of corrosion of stirrups, while the ultimate bearing capacity was enhanced obviously after PET sheet strengthening .The efficiency of PET wrapping decrased with increase of degree of corrosion of stirrups .Based on the test results , a reduction factor kpf reflecting effect of corrosion and shear strength prediction model of the corroded RC columns after PET wrapping were proposed ,whose calculated results agreed well with test values .