Abstract:The vertical hybrid structure is the structure with upper steel and lower concrete components (S/RC structure).Because of its advantages in architectures and structures,it has been used in critical engineering projects in China.However,the changes of the vertical stiffness of S/RC structure make the building performance more complex than the ordinary structures when subjected to seismic load.In this paper,in order to study the seismic behavior of a structure located in 6 seismic intensity (0.05 g) area,PERFORM-3D was used to perform elasto-plastic time history analysis.Besides,this paper analyses the deformation、dissipation 、whipping effect and failure mode,and evaluate its seismic behavior.The calculation results indicate that the inter story drift becomes dramatically at the floors where vertical stiffness changes and it is rational in the dissipation and can meet the requirement of the 3-level design.
What problem does this paper attempt to address?