Experimental Study on the Temperature Impacts on the CO2 & SO2 Removing Efficiency by Ammonia Gas Scrubbing

刁永发,王淑娟,陈昌和
DOI: https://doi.org/10.3321/j.issn:0253-2468.2004.05.014
2004-01-01
Abstract:This paper describes our studies on a novel CO_2 and SO_2 removal approach, ammonia and vapor spraying. The inlet concentrations of CO_2 and SO_2 are 12%, 0.25% (V/V), respectively. The temperature of vapor is 50℃ and was kept constant, thus the humidity is very low in the chemical reactor. The chemical reaction temperature was changed between 25℃~95℃. When spraying mixed gases with vapor and ammonia and the reaction temperature was in the range from 55℃ to 60℃, the maximum removal efficiency of CO_2 and SO_2 could reach 70% 95%, respectively. We analyzed the chemical reaction production by FTIR (Nicolet Company of USA), and showing that its by-product was the mixture of ammonium bicarbonate and vitriol. Combined with BET desorption experiments, the results showed that not only the CO_2 gases was scrubbed by ammonia, but also it could be adsorbed in the bore of crystal of (NH_4)_2SO_4 NH_4HCO_3.
What problem does this paper attempt to address?