Mass Transfer-Reaction Study on Flue Gas Desulfurization with Fly Ash and Waste Marble

吴忠标,余世清
DOI: https://doi.org/10.3321/j.issn:0253-2468.2002.06.016
2002-01-01
Abstract:Change of SO 2 removal efficiency and slurry pH value with process time for fly ash and waste marble were experimentally determined in a double stirred vessel. Mass transfer rate N m, liquid phase mass transfer coefficient k L, gas phase overall mass transfer coefficient K G, gas phase mass transfer coefficient k G, mass transfer coefficient ratio K G/ k G and enhancement factor E with different process time were calculated. Furthermore, mass transfer reaction process of fly ash and waste marble desulfurization was also analyzed. The experimental and calculated results showed that the reaction was controlled by liquid phase resisstance while inlet SO 2 volume proportion was 4000×10 -6 . The liquid phase resistance decreased with slurry pH value, and the ratio of liquid phase resistance to overall resistance was 90% at pH=4 5. The effect of reaction on mass transfer increased with slurry pH value, and SO 2 removal efficiency for fly ash and waste marble was about 70% at pH=6.
What problem does this paper attempt to address?