Experimental study on extinguishing of pool fire with compressed air foam system in road tunnel

Tao CHEN,Cheng HU,Zhiming BAO,Yang CHEN,Xianzhong ZHANG,Xuecheng FU,Rongji WANG,Lishuai JING,Jianjun XIA
DOI: https://doi.org/10.11731/j.issn.1673-193x.2017.07.005
2017-01-01
Abstract:To study the variation laws of temperature,thermal radiation intensity and hot smoke in the tunnel during the action process of compressed air foam on the 4.65 m2 gasoline pool fire,a 30 m × 6 m × 6 m experimental model of road tunnel was applied to investigate the fire extinguishing performance of compressed air foam system in road tunnel on pool fire.The results showed that the compressed air foam system in road tunnel had excellent fire control and extinguishing ability on the gasoline pool fire under the conditions that the supply intensity was 5.1 L/(min · m2) and the air-liquid ratio was 14 ∶ 1.The fire control time was 21 s and the fire extinguishing time was 27 s,and the foam properties were stable,with a strong capability of anti-reburning.The compressed air foam had little disturbance to the hot smoke layer in the tunnel,and would not cause the hot smoke descending to the lower part of the tunnel,so it would not influence the evacuation of people.Under the effect of compressed air foam,the duration time of high temperature above 100℃ would not exceed 150 s both at the top and side walls of the tunnel,and the thermal radiation intensity around the pool fire could be reduced to the safe range within 30 S.
What problem does this paper attempt to address?