Numerical Simulation on the Optimization of the Ventilation Mode in Subway Tunnel Cable Smoldering Fire

Fan WU,Juncheng JIANG,Ru ZHOU,Langjun SHI,Dong ZHAO
DOI: https://doi.org/10.3969/j.issn.1001-425X.2017.01.014
2017-01-01
Abstract:Compared with the subway tunnel cable fire ,the cable smoldering fire is of higher concealment and greater dan-ger .On the basis of the characteristics of the cable smoldering fire ,this paper uses the numerical method to conduct re-search on the toxic distribution of the pyrolysis products of the smoldering cable in different ventilation modes .Results show that a supply of 2 m/s air velocity to the tunnel cross-section cannot ensure the safety of the evacuees to a maximum ex-tent .However ,the optimal supply of the air velocity which meets the cubic polynomial relationship upon the arrival of the train can maximize the safe distance inside the train and will not affect the safety evacuation of the personnel .
What problem does this paper attempt to address?