Abstract:In this study ,regarding tailings sample as test sample and soil standard substance as quality control sample ,ar-senic content in tailings sample is determined by applying aqua regia water bath digestion -Atomic Fluorescence Spectrome-try and microwave digestion-Atomic Fluorescence spectrometry respectively and relatively more appropriate methods of de-termining content of arsenic in lead-zinc tailings are found out by comparing the whole process and results of the two meth-ods .It is shown that ,results of two methods to determine arsenic content are both in the range of standard soil sample rec-ommended value ,the relative standard deviation of microwave digestion to detrmine arsenic content is lower ,with better re-producibility of sample ,it also has higher speed and efficiency during the process of experiment .It is shown that microwave digestion determination result is closer to the true value of sample .