A Study on the Pretreatment Methods for Determination of Pb、Cd、Cu、Zn and Ni in Soil

QIN Fan-xin,DUAN Ting-ting
DOI: https://doi.org/10.3969/j.issn.1004-5570.2005.02.023
2005-01-01
Abstract:This article is a contrast test about pretreatment methods for soil samples, determination of copper、zinc and nickel with flame atomic absorption spectrometer and determination of lead and cadmium with graphite furnace atomic absorption spectrometer. Results display that digestion method and digestion evaporation for dryness or no evaporation have an influence on determination of heavy metals. Temperature of digestion system has an effect on recovery rate of lead with digestion method of HCl+HNO_3+ HClO_4. Both of the two methods of normal pressure digestion of HNO_3+ HClO_4+HF and closed container high-pressure digestion of HNO_3+ HClO_4+HF demand polytetrafluorethylene beaker.Because of not transparency, it is difficult to observe process of digestion clearly, which is easy to appear in evaporation to dryness. As a result, it aeffects results of determination.
What problem does this paper attempt to address?