Research on Removal of High Ammonia Wastewater Containing Sodium Sulfate by Membrane Absorption

Xiaole Wang,Keyan Tan,Yang Gao,Hong Yang
DOI: https://doi.org/10.16796/j.cnki.1000-3770.2016.05.006
2016-01-01
Abstract:The experiments were carried out to study the effect of various parameters on the transfer performance,and the experimental feasibility was identified.The results demonstrated that as the temperature decreased from 25.1 ℃ to 5.2 ℃,the overall transfer coefficient decreased by 44.7%.In addition,increasing pH from 9.5 tol 1.5 resulted in 800% enhancement in the overall transfer coefficient.The reaction solution through the membrane of a continuous process run,the overall transfer coefficient remained unchanged.When circulated the reaction solution,however,the overall mass transfer coefficient decreased gradually.With the mass concentration of Na2SO4 increased from 16.7 g/L to 150.3 g/L,the overall transfer coefficient increased by 14.6% and the permeate flux turned from positive to negative.In the stability experiment,with mass concentration of ammonia was 4 g/L,the polypropylene hollow fiber membrane run 32 d stably,ammonia removal rate remained above 95%,the overall mass transfer coefficient stabilized between 3.7~4.4 μm/s,and the leak phenomenon was not observed.
What problem does this paper attempt to address?