Event Vertex and Time Reconstruction in Large-Volume Liquid Scintillator Detectors

Li Zi-Yuan,Zhang Yu-Mei,Cao Guo-Fu,Deng Zi-Yan,Huang Gui-Hong,Li Wei-Dong,Lin Tao,Wen Liang-Jian,Yu Miao,Zou Jia-Heng,Luo Wu-Ming,You Zheng-Yun
DOI: https://doi.org/10.1007/s41365-021-00885-z
2021-01-01
Abstract:Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter. Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy. In this study, four event vertex and event time reconstruction algorithms using charge and time information collected by photomultiplier tubes were analyzed comprehensively. The effects of photomultiplier tube properties were also investigated. The results indicate that the transit time spread is the main effect degrading the vertex reconstruction, while the effect of dark noise is limited. In addition, when the event is close to the detector boundary, the charge information provides better performance for vertex reconstruction than the time information.