Horizontal Position Reconstruction in PandaX-II

D. Zhang,A. Tan,A. Abdukerim,W. Chen,X. Chen,Y. Chen,C. Cheng,X. Cui,Y. Fan,D. Fang,C. Fu,M. Fu,L. Geng,K. Giboni,L. Gu,X. Guo,K. Han,C. He,S. He,D. Huang,Y. Huang,D. Y. Huang,Z. Huang,X. Ji,Y. Ju,S. Li,Q. Lin,H. Liu,J. Liu,L. Liu,X. Lu,W. Ma,Y. Ma,Y. Mao,Y. Meng,P. Namwongsa,K. Ni,J. Ning,X. Ning,X. Ren,N. Shaheed,C. Shang,G. Shen,L. Si,A. Wang,H. Wang,M. Wang,Q. Wang,S. Wang,W. Wang,X. Wang,Z. Wang,M. Wu,S. Wu,W. Wu,J. Xia,M. Xiao,X. Xiao,P. Xie,B. Yan,J. Yang,Y. Yang,C. Yu,J. Yuan,Y. Yuan,X. Zeng,T. Zhang,L. Zhao,Q. Zheng,J. Zhou,N. Zhou,X. Zhou
DOI: https://doi.org/10.1088/1748-0221/16/11/p11040
2021-01-01
Journal of Instrumentation
Abstract:Dual-phase noble-gas time projection chambers (TPCs) have improved the sensitivities for dark matter direct search in past decades. The capability of TPCs to reconstruct 3-D vertexes of keV scale recoilings is one of the most advantageous features. In this work, we develop two horizontal position reconstruction algorithms for the PandaX-II dark matter search experiment using the dual-phase liquid xenon TPC. Both algorithms are optimized by the Kr-83(m) calibration events and use photon distribution of ionization signals among photomultiplier tubes to infer the positions. According to the events coming from the gate electrode, the uncertainties in the horizontal positions are 3.4 mm (3 9 mm) in the analytical (simulation-based) algorithm for an ionization signal with several thousand photon electrons in the center of the TPC.
What problem does this paper attempt to address?