Simulation study on performance optimization of a prototype scintillation detector for the GRANDProto35 experiment
Xiang-Li Qian,Hui-Ying Sun,Cheng Liu,Xu Wang,Olivier Martineau-Huynh
DOI: https://doi.org/10.1007/s41365-021-00882-2
2021-05-01
Nuclear Science and Techniques
Abstract:As a proposed detector, the giant radio array for neutrino detection (GRAND) is primarily designed to discover and study the origin of ultra-high-energy cosmic rays, with ultra-high-energy neutrinos presenting the main method for detecting ultra-high-energy cosmic rays and their sources. The main principle is to detect radio emissions generated by ultra-high-energy neutrinos interacting with the atmosphere as they travel. GRAND is the largest neutrino detection array to be built in China. GRANDProto35, as the first stage of the GRAND experiment, is a coincidence array composed of radio antennas and a scintillation detector, the latter of which, as a traditional detector, is used to perform cross-validation with radio detection, thus verifying the radio detection efficiency and enabling study of the background exclusion method. This study focused on the implementation of the optimization simulation and experimental testing of the performance of the prototype scintillation detector used in GRANDProto35. A package based on GEANT4 was used to simulate the details of the scintillation detector, including the optical properties of its materials, the height of the light guide box, and position inhomogeneity. The surface of the scintillator and the reflective materials used in the detector was optimized, and the influence of light guide heights and position inhomogeneity on the energy and time resolutions of the detector was studied. According to the simulation study, the number of scintillator photoelectrons increased when changing from the polished surface to the ground surface, with the appropriate design height for the light guide box being 50 cm and the appropriate design area for the scintillator being 0.5 m<span class="mathjax-tex">\(^2\)</span>. The performance of the detector was tested in detail through a coincidence experiment, and the test results showed that the number of photoelectrons collected in the detector was <span class="mathjax-tex">\(\sim 84\)</span> with a time resolution of <span class="mathjax-tex">\(\sim 1\)</span> ns, indicating good performance. The simulation results were consistent with those obtained from the tests, which also verified the reliability of the simulation software. These studies provided a full understanding of the performance of the scintillation detector and guidance for the subsequent operation and analysis of the GRANDProto35 experimental array.
physics, nuclear,nuclear science & technology