PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

A. Kallitsopoulou,R. Aleksan,Y. Angelis,S. Aune,J. Bortfeldt,F. Brunbauer,M. Brunoldi,E. Chatzianagnostou,J. Datta,D. Desforge,G. Fanourakis,D. Fiorina,K.J. Floethner,M. Gallinaro,F. Garcia,I. Giomataris,K. Gnanvo,F.J. Iguaz,D. Janssens,M. Kovacic,B. Kross,P. Legou,M. Lisowska,J. Liu,M. Lupberger,I. Maniatis,J. McKisson,Y. Meng,H. Muller,E. Oliveri,G. Orlandini,A. Pandey,T. Papaevangelou,M. Pomorski,L. Ropelewski,D. Sampsonidis,L. Scharenberg,T. Schneider,E. Scorsone,L. Sohl,M. van Stenis,Y. Tsipolitis,S.E. Tzamarias,A. Utrobicic,I. Vai,R. Veenhof,P. Vitulo,X. Wang,S. White,W. Xi,Z. Zhang,Y. Zhou
DOI: https://doi.org/10.1016/j.nima.2024.169920
2024-10-29
Abstract:The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.
Instrumentation and Detectors
What problem does this paper attempt to address?
The paper attempts to address the issue of improving the time resolution of gas detectors, particularly for time-stamping leptons (such as electrons and muons) in high-energy physics experiments. Specifically, the PICOSEC-Micromegas (PICOSEC-MM) detector aims to achieve picosecond-level high-precision time measurements by utilizing extreme ultraviolet Cherenkov light to eliminate time jitter in the ionization gap. ### Main Issues: 1. **Improving Time Resolution**: Existing Micro-Pattern Gas Detectors (MPGDs) have limitations in time resolution, unable to meet the requirements of future high-energy physics experiments. The PICOSEC-MM detector, through innovative design, improves the time resolution to the level of tens of picoseconds, significantly better than standard MPGDs. 2. **Handling High Event Rates**: In future high-energy physics experiments, high event rates will increase the complexity of event reconstruction, necessitating precise time information to distinguish different events. The PICOSEC-MM detector is designed to operate stably in high event rate environments while maintaining high time resolution. 3. **Application in the ENUBET Project**: This detector is particularly suitable for the ENUBET project, which aims to generate narrow-band neutrino beams and precisely control the flux, flavor, and energy of neutrinos. The PICOSEC-MM detector can be used to monitor related leptons in the neutrino beam, reducing the mixing of different events and improving the accuracy of event reconstruction. ### Key Technical Points: - **Extreme Ultraviolet Cherenkov Light**: Utilizing extreme ultraviolet Cherenkov light produced in a thin crystal, detected by a CsI photocathode, to avoid time jitter in the ionization gap. - **Dual-Stage Amplification Structure**: Using a Ne:C2H6:CF4 (80:10:10) gas mixture to achieve dual-stage amplification, enhancing signal strength. - **Multi-Pad Resistive Detector**: Designing a new 10M Ohm/□(cm²) resistive detector to improve stability and durability in high event rate environments. ### Experimental Validation: - **Single-Channel Prototype Testing**: Achieved a time resolution of less than 25 ps in a 150 GeV/c muon beam with a single-channel prototype. - **Multi-Pad Detector Testing**: Tested a 7-pad detector at the CERN SPS H4 secondary beamline, verifying its stable performance in high event rate environments. - **Electromagnetic Shower Testing**: Modified the experimental setup to test the detector's response to electromagnetic showers, achieving an average time resolution of about 30 ps. In summary, the paper successfully addresses the need for high-precision time measurements in high-energy physics experiments through the design and testing of the PICOSEC-MM detector, providing important technical support for future experiments.