Interferometric Method of Measuring External Cylindrical Surfaces

Qing Zhou,Junhua Wang,Min Xu
DOI: https://doi.org/10.1364/ao.412366
IF: 1.9
2020-01-01
Applied Optics
Abstract:A new method of measuring external cylindrical surfaces is proposed, making use of a ring beam transform unit. The unit is composed of three cone mirrors, with which a parallel beam can be transformed into annular and convergent beams. The method has advantages over classic methods: It avoids physical contact with the cylinder surface and is fast and stitching-free. In experiments using a dynamic interferometer to demonstrate the feasibility of the method, the RMS difference of the axis contour from results using a Luphoscan is 0.0282 µm, while the roundness difference of the circumferential contour is 0.0962 µm.
What problem does this paper attempt to address?