ANALYSIS OF THE STAINLESS STEEL BEAM-TO-COLUMN CONNECTION PANEL ZONE

Zihong Lin,Gang Shi
2016-01-01
Abstract:In order to study the behavior of the stainless steel beam-to-column connection panel zone, the finite element method (FEM) is applied for the numerical simulation. Based on the results of parametric analysis, the ratio between the actual moment resistance of the panel zone and its design moment resistance according to the steel structures design code, c=M(p)l(4/3f(v)V(p)) is discussed. It can be concluded that, the ratio c is mainly affected by the section sizes of beams and columns with the average value of c being 1.018 and standard deviation being 0.030. Therefore, it is safe to adopt 4/3f(v)V(p) as the design moment resistance of the panel zone for stainless steel structures, and the shear resistance check formula of the panel zone for stainless steel structures could be (M-b1+M-b2)<= 4/3f(v)V(p).