Effects of Iodine Contrast Agent Injected at Different Positions on Picture Quality Inspection of Multi Slice Spiral CT Carotid Artery Angiography

梅霞,董颖,桑燕,蒋蓓,李广红,张华,陈凤,张勤
DOI: https://doi.org/10.3760/cma.j.issn.1674-2907.2015.28.015
2015-01-01
Abstract:Objective To study the effects of iodine contrast agent injected at different positions on picture quality inspection of multi slice spiral CTA carotid artery angiography. Methods A total of 60 consecutive patents with neck CTA examination were selected and randomly divided into experimental group (n=30, built up venous access at right antecubital vein) and control group (n=30, built up venous access at left antecubital vein ) . We compared and statistically analyzed different injected positions impacting on the picture quality of neck CTA in two groups, utilized 5-point scale to assess the value of neck CT, intravenous hardening artifact, and effects of intravenous hardening artifact impacting on carotid artery. Results The value of peripheral vein CT in the experimental group was lower than that of the control group (t=28. 4,P<0. 05). The image evaluation of experimental group acquired average score (4. 5 ± 0. 8) and (3. 1 ± 1. 3) in the control group (Z=4. 2,P<0. 01). Conclusions CTA neck intravenous catheter puncture site should try to choose the right side of the upper extremity to establish intravenous access, so as to reduce venous generated artifacts and improve neck CTA image quality.