Consistency of Peer Assessment Rating Index by Computer 3D Digital Measurement and Manual Measurement

Song Guangying,Wang Xin,Teng Fei,Yu Mochen,Pei Ruyu,Xu Tianmin
DOI: https://doi.org/10.3760/cma.j.issn.1674-5760.2019.01.005
2019-01-01
Abstract:Objective To investigate the consistency between the computer-based 3D software semi-automatic measurement and the traditional manual measurement of Peer Assessment Rating (PAR) Index.Methods Cases of 39 patients were randomly selected from those completed in the period from 2014 to 2016 in Department of Orthodontics,Peking University School and Hospital of Stomatology.Methods of customized 3D model measurement and traditional manual measurement were used to evaluate the severity of malocclusion of the 39 cases before and after orthodontic treatment.The PAR index was applied for the measurement by multiple surveyors.The Bland-Altman plot,Kendall correlation coefficient and Wilcoxon signed rank test were used to analyze the consistency of these two methods of measurement.Statistical analysis was performed using MedCalc 18.2 and SPSS 24.0 software.Results For the distance measurement of anterior segment displacement of pretreatment casts,weak relevance between two methods was shown (P<0,001) and the limits of agreement was (-10.46 mm,3.83 mm),with 2.6% (1/39) points outside the 95% limits of agreement (95% LoA),which showed that data with digital measurement were smaller than manual measurement.The grading measurement of anterior displacement,buccal occlusion,overjet,overbite,and centerline of PAR index of pre-treatment casts had strong consistency (P<0.001,Kendall's correlation coefficients R=0.424、0.833、0.532、0.705、0.796).For the distance measurement of anterior segment displacement of post-treatment casts,it showed great consistency between two methods (P<0,001) and the limits of agreement was (-3.33 mm,3.07 mm),with none point outside the 95% limits of agreement(95% LoA).The grading measurement of anterior displacement and buccal occlusion of PAR index had great consistency (P< 0.001,R =0.486,0.596).No significant difference between the measurement of overjet,overbite and centerline of the PAR index (P>0.05).Conclusions In the measurement of PAR Index,semi-automated measurement of 3D software could replace manual measurement in most items.However,in terms of anterior segment displacement measurement,the results of two methods revealed a low consistency,which might be due to different reference planes.
What problem does this paper attempt to address?