A combined inspection technique for debonding defects in CFRP-strengthened steel structures based on leaky Lamb wave and low-power vibrothermography
Pengqian Liu,Changhang Xu,Yubin Zhang,Lina Chen,Rui Liu,Longbo Wang,Qing Zhao
DOI: https://doi.org/10.1007/s10973-024-13263-9
IF: 4.755
2024-05-26
Journal of Thermal Analysis and Calorimetry
Abstract:Debonding defects are inevitable during the fabrication or service of CFRP-strengthened steel structures, but there is a lack of sophisticated non-destructive testing techniques. Based on leaky Lamb wave (LLW) and low-power vibrothermography (LVT), a combined inspection technique is proposed for debonding defects of CFRP-strengthened steel structures. Firstly, LLW is used for qualitative detection of CFRP-strengthened steel structures by calculating the waveform energy as a detection index. Secondly, a sweep frequency-nonlinear response (SFNR) method based on the swept excitation, LLW, and nonlinear analysis is proposed to determine the optimal excitation frequency of LVT. Finally, LVT with optimal excitation frequency is used to quantitatively evaluate debonding defects. Experiments are performed to verify the effectiveness of the combined inspection technique. Results prove that the SFNR method significantly improves the LVT detectability of small-area defects. LVT thermal image sequences are processed using fast Fourier transform and Ostu segmentation, and the relative errors of defect quantification are in the range of 7.69–14.65%. In conclusion, the combined inspection technique provides an effective means to detect debonding defects in CFRP-strengthened steel structures during fabrication and in service.
chemistry, physical, analytical,thermodynamics