Development and Measurement of a Fast Kicker Magnet Applied to a Proton Therapy Facility

Wenjie Han,Guanqun Li,Bin Qin,Xu Liu,Dong Li,Qushan Chen,Chong Zhou
DOI: https://doi.org/10.1016/j.nima.2020.164094
2020-01-01
Abstract:A proton therapy facility based on spot scanning technique requires a fast ON/OFF beam switch during beam spots and energy modulation procedures. At HUST, a proton therapy facility (HUST-PTF) with multiple treatment rooms is under development. For HUST-PTF, this beam switch function is implemented by a fast kicker magnet and downstream beam dump. This paper introduces the development and measurement of this kicker magnet system, with main topics: (1) the development and measurement of the fast kicker magnet; (2) the corresponding pulsed power supply to implement the kicker function; (3) the dynamic magnetic field measurement system based on printed circuit board (PCB) technique.
What problem does this paper attempt to address?