A novel multi layer and multi zone redox FCC regenerator design for removing NOx gas system

Jun Li,Guohua Luo,Fei Wei
DOI: https://doi.org/10.3969/j.issn.0438-1157.2014.07.004
2014-01-01
Abstract:The development of NOx reduction strategy, the fluid catalytic cracking (FCC) regeneration process and the formation and conversion of NOx are summarized. O2 is a strong inhibiter of the reaction of NO reduction by CO. It should be an efficient NOx reduction way by controlling O2 concentration of the regenerator. A new type of a multi-layer multi-zone with oxidation zone and reduction zone NOx reduction technology is proposed. This new regeneration process could have characteristics of low carbon content, short regeneration time, high burning intensity, and counter-current contact with catalyst and air. In view of NOx reduction, regeneration temperature should be less than 700℃, CO concentration in regenerator no less than 4% and O2 concentration in regenerator less than 1% at least. This novel FCC regenerator technology is a highly efficient and economical NOx reduction technology, which has been demonstrated in the FCC plant of PetroChina Dagang Petrochemical Company, and might be applied to other FCC process or coal combustion for NOx reduction.
What problem does this paper attempt to address?