Error analysis of inpipe temperature measurement by thermocouple based on heat transfer computation

Li Zhang,Jianguo Luo,Qi Min,Xinxin Wu
DOI: https://doi.org/10.3772/j.issn.10020470.2014.07.009
2014-01-01
Abstract:The temperature distribution of a thermocouple which is applied to measurement of the temperature of a fluid in a pipe was computed based on the heat transfer theories, and the key factors affecting the temperature measurement accuracy were presented. The influence of the fluid’s temperature distribution in the pipe on the thermocouple’s measurement accuracy was studied, and the relationship between the insertion depth of the thermocouple’s thermowell in the pipe and the measurement error was analyzed. Then, a method for determining a rational insertion depth for a thermocouple was put forward based on example computions, and the results of computing the thermocouple insertion depth in industrial applications under several actual measurement conditions were given.
What problem does this paper attempt to address?