Simulation of the HTR-10Primary Mass Flow Variation Test

Fu-bing CHEN,Yu-jie DONG,Zuo-yi ZHANG,Yan-hua ZHENG,Lei SHI,Fu LI
DOI: https://doi.org/10.3969/j.issn.0258-0918.2017.02.007
2017-01-01
Abstract:The 10 MW high temperature gas-cooled reactor (HTR-10) is the first of its kind in China. The primary mass flow variation test is one of the three dynamic characteristic tests conducted on HTR-10. This test not only verifies the HTR-10 reactor power self-adjustment capability, but also provides measured data for the validation of system analysis codes. Based on actual test conditions, the primary mass flow variation test is simulated using the THERMIX code. Furthermore, main reactor parameters of interest are analyzed. The calculated reactor power agrees well with the test one, demonstrating that the HTR-10 dynamic characteristics can be reproduced satisfactorily by THERMIX. During the test process, the maximum fuel center temperature is always below its limit value of 1 230 ℃.
What problem does this paper attempt to address?