Fault Tolerance Control of Dual Three-phase Induction Machine with Two Phases Open

Weiwei SHI,Haifeng LU,Jianyun CHAI,Xudong SUN
DOI: https://doi.org/10.15934/j.cnki.micromotors.2017.01.008
2017-01-01
Abstract:The dual three-phase machine has more controllable freedoms.When the windings of the machine malfunction,it can maintain operation by proper control method,which increases the reliability of the whole system.This paper deduced the decomposition transformations and built the vector space decomposition models (VSD model) for the faulted machine with single and two isolated neutral points.According the control1able freedoms and derating factors,the fault tolerance currents of different running modes were calculated.The fault tolerance control was implemented by the proportion resonance controller (PR Controller) for every phase.Experiment results indicate that the fault tolerance control can suppress the pulsating speed and give the optimization performances according different optimize objects.
What problem does this paper attempt to address?