ULTRASONIC DETECION ON CRACK OF FRP ROD IN BRITTLE FRACTURE OF COMPOSITE INSULATOR

LIANG Xi-dong,DAI Jian-jun,ZHOU Yuan-xiang,CHEN Yi-fang
DOI: https://doi.org/10.3321/j.issn:0258-8013.2005.03.021
2005-01-01
Abstract:Brittle fracture is a severe mechanical failure accident of high voltage composite insulator, it occurs when insulator suffers a very low mechanical load. Up to now, researches have shown that it is a stress corrosion cracking leading to the brittle fracture of Fiber Reinforced Plastics (FRP) rod. According to the characteristic of brittle fracture in FRP rod, a method for detecting the crack in the cross-section of FRP rod using the oblique incident longitudinal waves of ultrasonic was presented, and a special ultrasonic transducer probe was made to detect the crack propagation in the process of brittle fracture of FRP rod. Test results show the variation of the amplitude of pulse-echo ultrasonic due to crack propagation in FRP rod subjected to tensile load and acid, and has a significant value for understanding the mechanism of brittle fracture of composite insulators.
What problem does this paper attempt to address?