Of fast machine protection system for the cads injection ι

Fang Liu,Jun Hu,Xiaoshan Jiang,Q. Ye,G. Gong
2016-01-01
Abstract:In this paper a new fast machine protection system is proposed. This system is designed for the injection Ι of CADS which fault reaction time requires less than 20 us, and the one minute down time requires less than 7 times in a whole year. The system consist of one highly reliable control network based on a control board and some front IO sub-boards, and one nanosecond precision timing system using white rabbit protocol. The control board and front IO sub-board are redundant separately. The structure of the communication network is a combination structure of star and tree types which using the 2.5 GHz optical fiber links the all nodes. This paper pioneered the use of nanosecond timing system based on the white rabbit protocol to determine the time and sequence of each system failure. Another advantage of the design is that it uses standard FMC and an easy extension structure which made the design is easy to use in a large accelerator. INTRODUCTION The injection Ι of ADS (Accelerator Driven Sub-critical System) is being constructed in institute of high energy physics, China [1]. How to ensure the safe and stable operation of the injection, the fast protection system has played a crucial role. The protection system needs to make a quick decision on the current failure. When a general failure, the system needs to quickly adjust the system without stopping and set the working state to the normal mode. When a serious fault, it is necessary to quickly send out a signal and shutdown the whole system. The system also cans storage the statement before and after the fault. Through the storage of information the staff can quickly rule out the reason of occurrence failure [2]. FAST MACHINE PROTECTION SYSTEM FRAMEWORK ADS fast protection system is composed of main control board, some front IO sub-boards, supervisory computer and one nanosecond precision timing system. The system framework is shown in Fig. 1. Front IO sub-board monitors the 24V or 5V switch signal from the LLRF, PS, Vacuum, RFQ and other critical points. When the monitored points occur error, it sends the error signal to the main control board through optical fiber. The signal contains the time information that is labelled by the White Rabbit system. The main control board analyses and judgments the error through the stored fault tree. Then, it issued the processing results to the front IO sub-boards. Meanwhile, the main control board WR SWITCH GPS/ RUBIDIUM OSCILLATOR/ SYSTEM REFERENCE CLOCK
What problem does this paper attempt to address?