1 FT / P 3-1 Commissioning Results of the KSTAR Cryogenic System

Y. S. Kim,Y. M. Park,Y. J. Lee,S. W. Kwag,Y. B. Chang,N. H. Song,I. S. Woo,T. H.,Park,K. W. Cho,H. S. Chang,D. S. Park,J. J. Joo,K. M. Moon,K. R. Park,Y. Chu,H.,Yonekawa,Y. O. Kim,E. N. Bang,H. K. Kim,K. P. Kim,M. K. Park,S. Baek. J. S. Hong,T.,H. Ha,Y. J. Kim,I. S. Hwang,H. L. Yang,Y. K. Oh,J. S. Bak,M. Kwon
2008-01-01
Abstract:The cryogenic system for the KSTAR superconducting magnets has been commissioned. It consists of a cold box, distribution boxes (DB) and cryogenic transfer lines. The cold box and DB #1 provide 600 g/s of supercritical helium to cool the superconducting (SC) magnets, their SC bus-lines, and the magnet support structures. It also provides 17.5 g/s of liquid helium to the current leads and supplies cold helium flow to the thermal shields. The cooling power of the cold box at 4.5 K equivalent is 9 kW which is extracted by 6 turboexpanders. The DB #1 includes 49 cryogenic valves, 2 supercritical helium circulators, 1 cold compressor, and 7 heat exchangers immersed in a 6 m 3 liquid helium storage bath. The main duties of the DB #2 are the relative distribution of the cryogenic helium among the cooling channels of each KSTAR cold component and the emergency release of over-pressurized helium during abnormal events such as quenches of the SC magnets. After individual commissioning, the system was integrated and cooled down with the KSTAR device. In this paper, the construction and commissioning results of the KSTAR cryogenic system will be introduced. In addition, we will present the cool-down results of the KSTAR device.