Performance Study and Optimization of a New Type of 4 K GM / PT Hybrid

Y Ju
2002-01-01
Abstract:We recently proposed and designed a new type of 4K GM/PT hybrid refrigerator, where the upper warm stage is a typical GM refrigeration cycle, and the cold stage is a pulse tube refrigerator, on which is thermodynamically coupled the upper warm stage. Four different types of phase shifting assembly were analyzed for adjustment of phase shift in the pulse tube. We show that the volume ratio of the regenerator to pulse tube, the volume ratio of the cold auxiliary piston to pulse tube, and the initial phase angle between the cold auxiliary piston and main displacer are of three most important parameters. In this paper, we briefly summarize our previous work and further optimize the hybrid refrigerator with respect to the structure parameters and geometrical configuration.
What problem does this paper attempt to address?