Ventilation Effects on Cavitation Induced-Vibration

王国玉,曹树良
DOI: https://doi.org/10.3969/j.issn.1003-1243.2001.02.007
2001-01-01
Abstract:To study the effects of ventilation on vortex cavitation induced-vibration around a hollow-jet valve,air was injected to the cavitating region in the valve.The cavitation aspects were observed.The intensity of cavitation vibration was measured whith an accelerometer mounted on the wall of the test section in conditions of ventilation and no-ventilation,respectively.A frequency analysis of the vibration was then conducted.It was found that the cavitation-induced vibration occurred in the frequency band from 10 tp 23 kHz.The vibration intensity was effectively suppressed by increasing the amount of ventilation into the separated region behind the needle of the model valve,especially,in small and middle cavitation number states.
What problem does this paper attempt to address?