Impacting Method for On-line Measurement of Solid Circulating Rate in CFB

胡南,姚宣,晁俊楠,杨海瑞,吕俊复
2011-01-01
Abstract:A flowmeter has been developed for measurement of solid flow rate by measuring the impact force between dropping particles and the target plate,of which the availability was experimentally verified.Influence of following factors on measurement of the flowmeter was analyzed,such as the dropping velocity,size and concentration of particles.A theoretical model of flowmeter was set up,to which verification tests were made using test data of cold-state circulating fluidized bed.Results show that the flowmeter is charaterized by facile operation,accurate measurement,fast response,easy calibration and little interference on gas-solid flow in the riser.The calculation results based on the model agree well with that of the experiment.Therefore the model may be used to simply the calibration process and subsequently enlarge the application range of flowmeters.
What problem does this paper attempt to address?