Reduced Graphene Oxide-Wrapped Palladium Nanowires Coated with a Layer of Zeolitic Imidazolate Framework-8 for Hydrogen Sensing
Abhishek Kumar,Mohammad Moein Mohammadi,Yaoli Zhao,Yang Liu,Jun Liu,Thomas Thundat,Mark T. Swihart
DOI: https://doi.org/10.1021/acsanm.1c01348
IF: 6.14
2021-08-13
ACS Applied Nano Materials
Abstract:Rapid and sensitive H2 detection is important because of its low threshold for the formation of explosive mixtures in air (∼4%). Palladium's unique interactions with H2 make it particularly useful in room-temperature H2 sensing, but the formation of water by reaction with O2 at the Pd surface can interfere with sensor response. Here, we report H2 sensors using networks of high aspect ratio and ultrathin reduced graphene oxide (rGO)-coated palladium nanowires (Pd ) with a coating of zeolite imidazole framework (ZIF-8) that serves as a nanofiltration layer. We first produced Pd NWs in high yield by a hydrothermal method, then sonicated them with GO and added a reducing agent to produce Pd Thin Pd NWs promote rapid response and high sensitivity, while rGO prevents the formation of additional conductive channels due to expansion of Pd NWs upon H2 exposure, ensuring monotonic sensor response. The coating of ZIF-8 reduces the transport of molecules like oxygen and nitrogen to the Pd NWs while allowing H2 to reach them and H2O to diffuse away from them. The optimized sensors showed a response (relative change in resistance) to 1% H2 in air of up to 2%, with a response time of 5 s and a lower limit of detection of 20 ppm. Relative to previously reported Pd-based H2 sensors with fast response, the Pd @ZIF-8 nanocomposite-based device provides a low-cost, high-performance sensor solution for fuel-cell vehicles and similar applications that require both rapid and sensitive H2 detection.The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acsanm.1c01348.FTIR spectra of GO and Pd ; representative EDS spectrum of a bulk Pd nanocomposite material; EDS spectrum of an individual Pd as obtained from STEM imaging; SEM image of a Pd sensor, SEM image of a Pd @ZIF-8 sensor and corresponding elemental mapping of the sensor; XPS spectrum of Pd for (a) Ca 2P, (b) O 1s; Pd NWs (c) C 1s, (d) O 1s; hysteresis curve and the corresponding dynamic H2 sensing curve for Pd NWs; response vs H2 concentration curve of and @ZIF-8 sensors; TEM images, dynamic H2 sensing performance, and EDS spectra of 2 ; comparison of sensor response to repeated exposure to 1% H2; response, response time, and recovery time of Pd NWs, Pd , and Pd @ZIF-8 H2 sensor; the response of @ZIF-8 sensor to 100 ppm of H2, CO, CH4, and CO2; and comparison of dynamic H2 sensor performance of the Pd @ZIF-8 sensor on day 1 and on day 150 (PDF)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology