A Pressure Drop Model for the Annular-Mist Flow in Vertical Venturi

Jinghan Wang,Ying Xu,Tao Zhang,Haitao Wu,Huaxiang Wang,Xiaoqian Huo
DOI: https://doi.org/10.1016/j.jngse.2020.103168
IF: 5.285
2020-01-01
Journal of Natural Gas Science and Engineering
Abstract:Venturi is one of the most commonly used flowmeters for measuring gas-liquid flow at the natural gas wellhead. A better understanding of the flow mechanism and the causes for pressure drop is necessary for the establishment of the measurement model. In this study, a one-dimensional pressure drop model between the two pressure taps of Venturi has been proposed for vertical annular-mist flow. The relations between the liquid film, entrainment rate, void fraction, and velocity slip have been revealed when the annular flow went through Venturi. We consider the gas acceleration in the throat of Venturi. The proportions of various pressure drops are given. The experimental results show that the relative errors of the pressure drop have a confidence probability of 98.5% within 10%. The predicted results are also in good agreement with the on-site data. It proves that the new pressure drop model has good performance.
What problem does this paper attempt to address?