Best Estimate Plus Uncertainty Analysis of Small Break Loss of Coolant Accidents with Different Break Sizes for CPR1000

Qingwen Xiong,Junli Gou,Jianqiang Shan
DOI: https://doi.org/10.1016/j.anucene.2019.107228
IF: 1.9
2019-01-01
Annals of Nuclear Energy
Abstract:The best estimate plus uncertainty (BEPU) is an advanced method which has been widely adopted in nuclear power plant safety analysis. In order to investigate the transient behaviors of the pressurized water reactor CPR1000 during the cold leg small break loss of coolant accident (SBLOCA) at different break sizes, BEPU analysis of the SBLOCA was carried out in this study, and the sizes of the break were 0.2%, 0.4%, 0.6%, 0.8% and 1.0% of the cross-sectional area of the cold leg, respectively. The minimum collapsed level (MCL) in the active core section was determined to be the figure of merit (FOM). The base case calculations, uncertainty propagation calculations and sensitivity analysis calculations were performed with the NUSOL-SYS code. Based on the results, the transient behaviors were analyzed, the lower 95/95 tolerance limits of the MCL at different break sizes were quantified, and the important input parameters were determined. (C) 2019 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?