Dynamics of Hybrid Processes with Mixed Solvent for Recovering Propylene Glycol Methyl Ether from Wastewater with Different Control Structures

Yao Dai,Ying Xu,Shuai Wang,Shuhua Li,Yinglong Wang,Jun Gao
DOI: https://doi.org/10.1016/j.seppur.2019.115815
IF: 8.6
2019-01-01
Separation and Purification Technology
Abstract:It is important to investigate the dynamic controllability of hybrid extraction-distillation with mixed solvent due to economic factors and control. The dynamic control of the hybrid extraction-distillation with mixed solvent is complex due to the proportions of the mixed solvent and hybrid extraction-distillation. In this paper, the dynamic control process of the hybrid extraction-distillation using a mixed solvent (70 mol% chloroform and 30 mol% 2-ethylhexanoic acid) was studied. During the dynamic control process, four control structures were evaluated via feed disturbances. Three control structures (fixed reflux ratio, reflux ratio/feed flow rate, and heat duty of reboiler/feed flow rate) achieved good performance when introduced with +/- 20% feed flow rate disturbances. The composition-reflux ratio cascade control structure can achieve good performance when introduced with +/- 20% feed composition disturbances. In terms of the total annual cost and carbon emissions, the mixed solvent process is superior to the single solvent process. However, in terms of the control effect, the single solvent process is superior to the mixed solvent process. The dynamic controllability of hybrid processes with mixed solvent basically meets the product purity requirements and demonstrates economy. This paper provides guidance for industrial green production.
What problem does this paper attempt to address?