The Dead Time Characterization Method of Quartz Flexure Accelerometers Using Monotonicity Number

Bin Wu,Lingyun Ye,Tiantian Huang,Zhaowei Yang,Kaichen Song
DOI: https://doi.org/10.3390/s19143123
IF: 3.9
2019-01-01
Sensors
Abstract:Dead time estimation is important in the design process of quartz flexure accelerometers. However, to the authors’ knowledge, the dead time existing in quartz flexure accelerometers is not well investigated in conventional identification studies. In this paper, the dead time, together with the open-loop transfer function of quartz flexure accelerometers, is identified from step excitation experiments using two steps. Firstly, a monotonicity number was proposed to estimate the dead time. Analysis showed that the monotonicity number was robust enough to measurement noise and sensitive to step excitation. Secondly, parameters of the open-loop transfer function were identified using the least mean squares algorithm. A simulation example was applied to demonstrate the validity of the proposed method. The verified method was used to test a quartz flexure accelerometer. The experimental result shows that the dead time was 500 μs.
What problem does this paper attempt to address?