Flammability Characteristics of the Battery Vent Gas: A Case of NCA and LFP Lithium-Ion Batteries During External Heating Abuse

Weifeng Li,Hewu Wang,Yajun Zhang,Minggao Ouyang
DOI: https://doi.org/10.1016/j.est.2019.100775
IF: 9.4
2019-01-01
Journal of Energy Storage
Abstract:The purpose of this research was to evaluate the safety of lithium-ion batteries (LIBs) from the perspective of the flammability characteristics of the battery vent gas (BVG). The BVG released by commercial 18650 LIBs with Li-x(Ni0.80Co0.15Al0.05)O-2 (NCA) and LixFePO4 (LFP) cathodes during external heating abuse was used to study its flammability characteristics at diferent state of charge (SOC). Flammability characteristics included the upper flammability limit (UFL), lower flammability limit (LFL), flammability range (R-F), flammability hazard index (H-F), LIB fire safety threshold (SOCF), and diluent ratio threshold (DRF). Effects of external carbon dioxide (CO2) on the flammability characteristics of the BVG were also studied. The results show that the UFL and LFL curves of the BVG form a peninsula shape for both types of batteries as the SOC decreases, with R-F being essentially unchanged first and then decreased dramatically. For the LFP battery, the LFL of the BVG is higher, and the R-F is lower, resulting in obviously lower H-F than those of the NCA battery at the same SOC. Using CO2 dilution can significantly reduce the BVG flammability and extend the SOCF. At the same SOC, the DRF is obviously lower for LFP LIBs than the NCA type.
What problem does this paper attempt to address?