Accuracy of a Chairside Fused Deposition Modeling 3D-Printed Single-Tooth Surgical Template for Implant Placement: an in Vitro Comparison with a Light Cured Template

Yao Sun,Qian Ding,Lin Tang,Lei Zhang,Yuchun Sun,Qiufei Xie
DOI: https://doi.org/10.1016/j.jcms.2019.03.019
IF: 3.192
2019-01-01
Journal of Cranio-Maxillofacial Surgery
Abstract:PURPOSE:To compare the accuracy of a chairside fused deposition modeling (FDM) 3D-printed surgical template with that of a light-cured template for implant placement.MATERIALS AND METHODS:Twenty standard mandibular resin models with missing teeth 36 and 46 were selected. Surgical templates were fabricated using a chairside FDM 3D-printer (test group) or a light-curing 3D printer (control group) (n = 20/group). Forty implants were placed by a clinician blinded to group allocation. The angular, 3D, mesiodistal, buccolingual, and apicocoronal deviations at the implant base and tip between preoperative design and postoperative implant position were recorded.RESULTS:The mean angular (test vs control groups: 3.22° ± 1.55° vs 2.74° ± 1.24°, p = 0.343) and 3D deviations at the implant base (test vs control groups: 0.41 ± 0.13 mm vs 0.35 ± 0.11 mm, p = 0.127) and tip (test vs control groups: 0.91 ± 0.34 mm vs 0.75 ± 0.28 mm, p = 0.150) were similar. The mesiodistal, buccolingual, and apicocoronal deviations at the implant base and tip also did not differ significantly between groups (p > 0.05).CONCLUSIONS:For single tooth gap indications, implant placement with an FDM 3D-printed surgical template was as accurate as that with a light-cured template, and more efficient.
What problem does this paper attempt to address?