Optimization Of Pmuts Driving Waveform Based On Phase Delay To Reduce Attenuation Vibration

Xinxin Liu,Xuying Chen,Xianhao Le,Zhonggui Xu,Changju Wu,Jin Xie
DOI: https://doi.org/10.1109/NEMS.2018.8556895
2018-01-01
Abstract:This paper proposes optimization of driving waveform for piezoelectric micromachined ultrasonic transducers (pMUTs) based on phase delay method. The optimized driving form can effectively improve emission efficiency and shorten the blind, which directly indicates shortened blind area in pulse-echo ultrasonic distance measurement. The phase delay method effectively restrains the pMUT's attenuation vibration within 20 nm in air and 15 nm in water swiftly. This method can save attenuation time varying from 45.9 similar to 206 mu s in air and 78.9 similar to 130.1 mu s in water respectively. When applied in ultrasonic rangefinders, this method can shorten the blind area by 35 mm in air and 97.6 mm in water respectively. Furthermore, in some particular circumstance where less pulses are preferred as excitation, the ratio of emission time to vibration time can be greatly improved in high Q factor transducer, then enhance the emission efficiency.