Development of a 15 W at 80 K Coaxial Pulse Tube
N. Wang,M. Zhao,X. Liu,L. Wei,Q. Zhu,H. Chen,J. Liang
2018-01-01
Abstract:To meet the demands of the high capacity cryocoolers used in space applications, the Technical Institute of Physics and Chemistry (TIPC) has successfully developed a high-capacity pulse tube cryocooler. The cryocooler is driven by a long-life linear compressor which consists of two dualopposed pistons and a maximum swept volume of 10cc. In this paper, the operating frequency was optimized by adjusting the inertance tubes, and the performance of the pulse tube cryocooler has been tested over a wide range of electrical powers. When the operating frequency is 44 Hz and the a no-load temperature of about 32K. Its typical is cooling performance of 15W at 80K under an input electrical power of 230W and a reject temperature of 293K. When 100W of electrical power INTRODUCTION Given that the pulse tube cryocooler (PTC) has no moving parts in its cold head, it demonstrates a greater reliability than the Stirling refrigerator in many space applications. In recent years, many PTCs have been sent to the space, and they all have been working well for years [1]. With the development of space technology, there are many aerospace applications which require very large cooling capacity cryocoolers. The optical components of large earth surveillance satellites have high heat loads, which must be cooled by high-capacity cryocoolers. To meet the current demands, in 2007, Sunpower Inc. developed a single-stage coaxial PTC, named CPT60, and it achieved 7.2W cooling power at 80K with 145W input power [2]. In the same year, Thales had developed and tested the LPT9710 coaxial pulse tube cooler which produced a cooling power of at least 15W at 80K [3-4]. In 2010, the Key Laboratory of Cryogenics, TIPC/CAS, developed a coaxial PTC named CPTC-10, which obtained a capacity of 10W power at 77K and a relative single-stage PTC for space-borne optics cooling, which typically provided a cooling power of 10W 90K [6]. After 5 years, they developed a 10W at 70K PTC for cooling infrared focal-plane array in These exciting results indicate that the high capacity PTC is available. However, there still needs efforts to improve the COP, reduce the weight and increase the cooling power. The Key Laboratory Cryocoolers 20, edited by S.D. Miller, R.G. Ross, Jr. and J.R. Raab ©¶International Cryocooler Conference, Inc., Boulder, CO, 2018 155 of Space Energy Conversion Technologies of TIPC, CAS has been conducting the research on coaxial PTCs for more than 20 years. Many coaxial PTCs were developed with the capacity varying from hundreds of milliwatts to greater than 15W at the cooling temperatures ranging from 20K to 180K. In recent years for the single-stage coaxial PTCs operating at 80K, much effort has been paid to increase the cooling capacity to meet the requirement of some large aerospace applications. In 2014, we developed a 9W at 80K coaxial PTC for superconductor research. In 2017, a 13W at 80K coaxial PTC was designed in our group with a corresponding electric power of 300W [8]. In this introduced. The optimization of the phase shifter and compressor is discussed in details. Moreover, the operating performance of the PTC is presented at the end of this paper. OPTIMIZATIONS OF PTC Figure 1 shows the schematic of the single-stage coaxial PTC. It uses a dual-opposed piston linear compressor with a maximum swept volume of 10 cc. The working gas is helium and the charge pressure is 4.0 MPa. Constant 500 mesh stainless steel stacked screens are used as the regenerator matrix. The cooler optimization is based on the above operating parameters. Optimization of phase shifters large. According to primary research, a single inertance tube with a constant diameter has a great challenge in obtaining the desired phase relationship. Thus, a three-segment inertance tube with different diameters and lengths is selected to achieve a suitable phase shift. Table 1 shows the combinations of inertance tubes. Figure 2 illustrates cooling performance of the the PTC with Case 1 has the lowest cold-end temperature. Therefore, the Case 1 is the best combination of inertance tubes, and at this condition the optimal frequency of the PTC is tested to be 44Hz. Optimization of compressor Figure 1. The schematic of the PTC: 1 Compressor, 2 Inertance tube and reservoir, 3 Hot-end exchanger, 4 Pulse tube, 5 Regenerator, 6 Cold-end exchanger 156 MED. CAPACITY 50 200 K SINGLE STAGE CRYOCOOLERS Table 1. Combinations of inertance tubes Case Combinations of inertance tubes Case 1 2.5mm×0.5m+ 3mm×2m+ 4mm×2m Case 2 2.5mm×1m+ 3mm×2m+ 4mm×2m Case 3 2.5mm×0m+ 3mm×2m+ 4mm×2m Case 4 2.5mm×0.5m+ 3mm×1m+ 4mm×2m Case 5 2.5mm×0.5m+ 3mm×2.5m+ 4mm×2m Case 6 2.5mm×0.5m+ 3mm×2m+ 4mm×1m Figure 2. The cooling performance of the PTC with different inertance tubes Figure 3. The performance of PTC with two compressors DEVELOPMENT OF 15 W 80 K COAXIAL PT CRYOCOOLER 157