The Relationship of Wearing with the Abduction Angle of the Acetabulum in Total Hip Arthroplasty

戴雪松,严世贵,何荣新,王祥华,黄宗坚
DOI: https://doi.org/10.3760/j.issn:0253-2352.2002.05.001
2002-01-01
Abstract:Objective A group of total hip arthroplasties were followed up radiologically to in ves-tigate the relationship of the cup ab duction angle with the extent of wearing and its direction and the effects of the cup abduction angle on the stability of hip joint.Methods A series of 32hip joints(30patients)were followed up routinely.The average f ollow-up period was 4.2years.The cu p abduction angle was measured,and the sagittal displacement of fem oral head to acetabulum was also exam ined to determine the direction and degree of linear polyethylene wear.The direction and magnitude of wear were decided by measuring femoral head penetration into the polyethylene liner.A new method of computer assisted two dimensional wear mea-surement was employed in this study.The results were statistically analyzed,with a P value less than 0.05indicating significant difference.Results There were no evidences of component loosening and clinical failure among the 32hips at a latest f ollow-up.The angle between the axis femoral component and femoral shaft in all of the patients was less than 3d egrees.The average amount of linear wear was 0.81mm,and the wear rate was 0.18mm per year.The average cup abduction angle was 54.5degrees,the wear direction was?6.93degrees superior-laterally.Wear d irection had a negative correlation with cup abduction angle by linear re-gression analysis;it meaned that th e direction of wear turning from superior-medial to superior-lateral gradually along with the increasing of cup abduction angle.In the cup abduction angle of more than 55degrees,the wear direction mostly orientated superior-laterally.However,no correlation of linear wear amount with wear di rec-tion or cup abduction angle was found in linear regression analysis.Conclusion Wear direction and cup abduction angle is negatively corre lated.The wear direction points mostly superior-laterally with cup abd uction angle over 55degrees,which could re sult in uneven stress distribution a nd greater stress concentration sup e-rior-laterally,consequently increase of wear;meanwhile,if the cup is too vertical,the risk of impingemen t and dislocation increases.The study shows that acetabular components with cup abduction angle over 55de-grees should be avoided in order to ma intain hip stability and desirable r ange of motion.
What problem does this paper attempt to address?