Development of Small-Sized High-Precision Frequency Standard Comparison System Based on DSP

唐升,刘娅,李孝辉
DOI: https://doi.org/10.3969/j.issn.1674-0637.2012.04.003
2012-01-01
Abstract:On the basis of analysis of the limitation of the traditional dual mixer time difference method, a digital method to achieve high precision of frequency standards measurement is proposed, and a new frequency standards comparison system towards such frequency standards as 5 MHz and 10 MHz is presented in this paper. The system is designed by adopting some new and original technologies, such as sinusoidal beat technology, synchronous sampling technology and digital signal processing technology. The experiment results verify that the noise floor of the system is about 1 × 10^-12/s for 10 MHz frequency standard. Since the system has the characters of high precision, small volume and low cost, it is of great value of application and dissemination in the field of time/frequency measurement.
What problem does this paper attempt to address?