Calibration of Stewart Platforms Using a Coordinate Measuring Machine

YAN Hao,HE Jingfeng,HUANG Qitao,HAN Junwei,LI Hongren
DOI: https://doi.org/10.3969/j.issn.1001-3881.2007.07.004
2007-01-01
Abstract:Aimed at the kinematics accuracy problem of the Stewart platform in the space docking hybrid simulation system,a effective calibration technique with low cost by using a general coordinate measuring machine was presented.The main idea is to acquire the position and orientation information of the platform by the coordinate measuring machine and construct a residual equation with uniform units.Then the geometry parameters of platform can be identified to compensate for its kinematics errors.The advantages of this method are that the identifiability of each geometry parameter is ensured;no special auxiliary calibration equipments or redundant sensors are required to be designed and manufactured;high adaptability and good operating characteristic are available.The calibration procedure was described and the strategy on constructing the residual equation was discussed,a simulation shows that the kinematics accuracy after calibration can reach the same order of magnitude as measurement noises.Applying this method to an actual Stewart platform,the accuracy improves more than 5 times after compensation.
What problem does this paper attempt to address?